Fire-Resistant Steel Door T30-1-FSA "Teckentrup DF"

Add to Text-Manager
Unity: pieces
Fire-Resistant Steel Door
T30-1-FSA "Teckentrup DF"
T30-1-FSA fire-proof steel door tested in accordance with DIN 4102.
Single-leaf door element. Type of handling DIN right. Door leaf
galvanized and prime coated similar to RAL 9002 (grey white).
52 mm thick, thick rebated on 3-sides. Sheet thickness 1.0 mm.
Galvanized and prime coated corner frame similar to RAL 9002
(grey white). 2 mm thick, with 3-sided seal. Mortice lock with
lever/knob in accordance with DIN 18250, prepared for profile cylinder.
Black plastic handle set. Handle pivoted on bearing with
tumbler insert (Bb) and 1 Bb key. 2 security bolts. FE/KO hinge set
with ball bearings.
“Teckentrup DF” (approval no.: Z-6.20-2037) or equivalent.
   
Building authority approval:
Z-6.20-2037 tested in acc. with DIN 4102
 
Approved dimensions:
Modular dimensions
Width: 625 - 1350 mm
Height: 1750 - 3000 mm
with Upper casing (Door leaf: 62 mm):
Height: 4000 mm
   
Standard sizes (mm):
( ) 750 x 2000
( ) 750 x 2125
( ) 875 x 1875
( ) 875 x 2000
( ) 875 x 2125
( ) 1000 x 2000
( ) 1000 x 2125
( ) 1125 x 2000
( ) 1125 x 2125
( ) 1250 x 2000
( ) 1250 x 2125
( ) 1250 x 2250
   
( ) Special size:
From 625 x 1750 mm to 1350 x 3000 mm
Width: ______ mm
Height: ______ mm
   
Door leaf:
( ) Sheet thickness 1,5 mm
   
Special equipment frame:
( ) Block frame
( ) Counter frame
( ) Closed frame
- installation in lightweight construction stud walls,
required:
( ) Counter frame
( ) Closed frame
- Installation in autoclaved aerated concrete without counter frame
for doors up to 1250 x 2250 mm without glazing
   
Glazing:
Fire-resistant glass “Promaglas 30”
17 mm thick with steel glass holding strips
galvanized and prime coated, grey white similar to RAL 9002.

Standard glazing (mm):
( ) 140 x 820
( ) 210 x 820
( ) 335 x 820
( ) 460 x 820
( ) 585 x 820
( ) 210 x 1280
( ) 335 x 1280
( ) 460 x 1280
( ) 585 x 1280
( ) Ø 300
( ) Ø 400
( ) Ø 500
   
Special glazing:
window section
Width: ______ mm
Height: ______ mm
   
Special equipment:
( ) Steel glass holding strips with additional aluminium cover strips  
( ) Stainless steel round glazing holding strips
( ) Stainless steel rectangular glazing holding strips
   
Special equipment:
Handle sets / Lever/Knob sets:
( ) Plastic
( ) Light metal
( ) Stainless steel
( ) With short plate
( ) With rose escutcheon (various makes)
( ) Prepared for rose escutcheon
   
Locks
( ) Profile cylinder 40.5 + 30.5 mm (door leaf 52 mm)
( ) Profile cylinder 45.5 + 35.5 mm (door leaf 62 mm)
( ) panic locks 35,5 + 45,5 mm
Block lock (must be provided/can also be supplied)
( ) Panic handle bar

( ) Top door closer DIN EN 1154
( ) Head assembly
( ) With slide rail
( ) With locking device
( ) With smoke detector
( ) ITS 96 (hidden) 62 mm 
( ) For doors with glazing with top door closer
( ) For installation in lightweight construction stud walls with top door closer
( ) For installation in autoclaved aerated concrete walls with top door closer
   
( ) Bottom door closer DIN EN 1154
   
( ) Electric door opener
( ) Integrated lock inspector (bolt contact)
( ) Integrated opening indicator (Reed contact)
( ) Revolving door drives
( ) Hold-open devices
( ) Floor seals can now be retrofitted
   
Special equipment:
( ) Smoke proof in acc. with DIN 18095 with top door closer for solid
and lightweight construction stud walls
Sound insulation in acc. with DIN EN 20140\717 Part 1
( ) RW 38 dB with retractable bottom seal
( ) RW 42 dB with buffer strip

( ) Burglar-resistant in acc. with DIN V ENV 1627-WK 2
(up to a width of 1250 x height of 2500 mm)
   
* ( ) please mark
   
Manufacturing certificate:
Teckentrup GmbH & Co. KG
Industriestr. 50
D-33415 Verl - Sürenheide
Tel.: +49 (0) 52 46/5 04-0
Fax: +49 (0) 52 46/5 04-230
URL: http://www.teckentrup.biz
Email: info@teckentrup.biz