Sectional Door Double-Skinned Type SW "Teckentrup"

Add to Text-Manager
Unity: pieces
Sectional Door Double-Skinned Type SW "Teckentrup"
Sectional door double-skinned PUR foam core. Building depth 40 mm. Outer
surface stucco design. Inner surface smooth, uniformly arranged, horizontally
ribbed sections. Colour similar to RAL 9002 (grey white). Special lock with
automatically locking catches. Round handle set with profile cylinder. Sections
with centre seal. EPDM header seal and floor seal and lateral protective strip.
Screwed hinges made of galvanized steel, lateral roller guide with adjustable
ball bearing rollers. Weight compensation with torsion spring shaft with lateral
load-bearing cables.
“Teckentrup SW” or equivalent.

Ordering dimensions:
Clearance dimensions:
______ mm wide and
______ mm high
are = clear opening dimensions
Ordering details:
Headroom: ___mm
Lateral right-hand buffer _____mm, left-hand buffer _____mm
(for clearance refer to special equipment)
( ) With wicket door
( ) Without wicket door

Dimensions:   
Modular dimensions:
Width:  2250 – 8000 mm
Height: 1875 – 6000 mm
(other dimensions on request)

Fitting:  
( ) N:  Normal fitting
( ) ND: Normal fitting which follows the shape of the roof
( ) HL: High lift runner rail fitting
( ) HLD: High lift runner rail fitting which follows the shape of the roof
( ) NSH: Low headroom fitting with rear spring shaft
( ) NSD: Low headroom fitting which follows the shape of the roof
( ) VL: Vertical fitting
( ) VLU: Vertical fitting with lower torsion spring shaft

Special equipment:
( ) NS = Low headroom fitting with rear spring shaft
( ) HL = High lift runner rails
( ) VL = Vertically guided runner rails
( ) Types of fittings N, NS and HL also possible
as fittings which follow the shape of the roof.

Required space:
Lateral buffers:
( ) for manual operation on both sides min. 110 mm
( ) for geared chain on geared chain side min. 185 mm
( ) for direct mount drive on drive side min. 210 mm
( ) for chain drive on drive side min. 150 mm
( ) for axial chain min. 165 mm

NSH / NSD / NSV:
( ) Required side space 120
( ) Required space geared chain 185
( ) Required space direct mount drive 210
( ) Required space chain drive 150
( ) Required space axial chain 165

Headroom:
( ) for N fitting up to door height
3600 mm min. 400 mm
3610 - 5500 mm min. 450 mm
5510 - 7500 mm min. 500 mm
 
( ) for NS fitting up to door width  
4500 mm min. 250 mm
above door width 4500 mm min. 320 mm
( ) Doors with wicket door min. 320 mm

( ) for HL fitting always specify the headroom
( ) for VL min. headroom = 2 x door height + 500 mm

Drives:
( ) Manual chain hoist (geared chain)
( ) Electric drive as shaft or chain drive, 3 x 230 V or
400 V. 50 Hz, power: 0.37 kW/0.42 kW, degree of
protection IP 44
( ) Electric drive, rail-guided, 230 V, 50 Hz
( ) Control: Deadman, impulse with self-monitoring test
( ) Other controls possible

* ( ) please mark

Manufacturing certificate:
Teckentrup GmbH & Co. KG
Industriestr. 50
D-33415 Verl - Sürenheide
Tel.: +49 (0) 52 46/5 04-0
Fax: +49 (0) 52 46/5 04-230
URL: http://www.teckentrup.biz
Email: info@teckentrup.biz