Sectional Door Double-Skinned Type SW80 "Teckentrup"

Add to Text-Manager
Unity: pieces
Sectional Door Double-Skinned Type SW80 "Teckentrup"
Sectional door SW 80, door leaf made of individual, double-skinned galvanized
sheet steel door sections, building depth of the sections = 80 mm, polyurethane
(PU) foam core. Thermally separated sections. Grey white, similar to RAL 9002.
Floor seal (x2), header and central seal in EPDM quality. Outer surface micro-
profiled UNribbed, inner surface stucco design (alternatively outer surface
ribbed and stucco design). Laterally closed, 2-sided angular frame, with screwed-
on runner rails and double side seal, made of galvanized steel, including lateral
guards. Heat insulation (UD = W/m²K) 0.58 (for installed door 25m² door surface)
UD = 0.27 W/m²k (panel)
"Teckentrup" or equivalent.

Supply and install according to the manufacturer’s instructions.

Ordering dimensions:
Clearance dimensions:
_____mm width and
_____mm height are = clearance dimensions

Ordering details:
Headroom: _____mm
lateral buffer right _____mm, left _____mm
(for clearance, refer to special equipment)

Dimensions:
Modular dimensions
Width: 2,250 – 10,000 mm
Height: 1,875 – 8,000 mm
(other dimensions on request)

Fittings:
( ) N = Normal fitting
( ) ND = Normal fitting with roof incline
( ) HL = High lift runner rail fitting
( ) HLU = High lift runner rail fitting with bottom torsion spring shaft
( ) HLD = High lift runner rail fitting with roof incline
( ) HLDU = High lift runner rail fitting with roof incline and bottom torsion
spring shaft
( ) NSH = Low headroom fitting with rear spring shaft
(not for doors with a direct drive system)
( ) NSD = Low headroom fitting with roof incline
(not for doors with a direct drive system)
( ) VL = Vertical fitting
( ) VLU = Vertical fitting with bottom torsion spring shaft

Door dimensions with door width < 6,000 mm and door height
< 5,000 mm with a torsion spring shaft
Door dimensions with door width up to 10,000 mm or door height
up to 8,000 mm with a direct drive system

 

Required space for doors with torsion springs:
Lateral buffers:
( ) for manual operation min. 110 mm at both sides
( ) for geared chain at geared chain side min. 185 mm
( ) for shaft drive at drive side min. 210 mm
( ) for chain drive at drive side min. 150 mm

NSH/NSD:
( ) required sideroom 120
( ) required space for geared chain 185
( ) required space for shaft drive 210
( ) required space for chain drive 150

Required space for doors with a direct drive system:
Lateral buffers:
( ) drive side (direct drive system) = 300 mm
( ) bearing side = 150 mm

Headroom for doors with torsion springs:
( ) for N fitting up to door height
Up to door height < 3,600 mm: 400 mm
Door height > 3,601; < 5,500mm: 450 mm
Door height > 5,501 mm: 500 mm

Headroom for doors with a direct drive system:
( ) for N fitting 600 to 700 mm (size dependent)

( ) for NSH fitting min. 310* mm
* 290 mm possible on request
(not available for doors with a direct drive system)

( ) for HL fitting always specify the headroom
( ) for VL fitting min. headroom = 2 x door height + 500 mm
( ) for direct drive system 2 x door height + 700

Glazing:
( ) sandwich glazing type SW-80
    triple glazing, black plastic, rectangular
    dimensions: 829 x 407 mm (wxh)

Operation:
Manual operation:
( ) manual chain hoist, sliding bolts, spring break protection
Electrical operation:
( ) shaft drive TAS, 400 V 3ph, 60% ED (power-on time), IP 65, emergency crank handle
( ) deadman control CS 100, IP 65,control voltage 24 V, fully wired, with digital limit switches (AWG)
( ) pulse control CS 300, IP 65 incl. safety edge mechanism via optical sensor, control voltage 24 V,
fully wired, with digital limit switches (AWG)
( ) direct drive system TAR, 400 V 3ph, 60% ED (power-on time), IP 54, emergency crank handle
( ) deadman control CS 300, IP 65, control voltage 24 V, fully wired, with digital limit switches (AWG)
( ) other controls possible

* ( ) Please tick as appropriate

Manufacturing certificate:
Teckentrup GmbH & Co. KG
Industriestr. 50
D-33415 Verl - Sürenheide
Tel.: +49 (0) 52 46/5 04-0
Fax: +49 (0) 52 46/5 04-230
URL: http://www.teckentrup.biz
Email: info@teckentrup.biz